Single core double insulated meter tales 300/500V
(size 10mm to 25mm)

Single core double insulated meter tales 300/500V ( size 10mm to 25mm)
   
Price:  Negotiable View More
Min. Order ( Rolls) Unit Price
10 Negotiable
Trade Terms:  FOB, EXW, CFR, CIF, CIP
Payment Terms:  L/C, T/T
Price Valid Time:  From Jul 09, 2012 To Jul 01, 2013

Basic Info.

Insulation Material:  PVC
Conductor Type:  Solid
Conductor Material:  Copper
Application:  Overhead
Type:  Insulated
Jacket:  PVC
Rated Voltage:  450/750V 300/500V
Export Markets:  Global

Additional Info.

Trademark:  huataitelan
Packing:  in Coils
Standard:  100m/coil or according to customer's requirement
Origin:  Lahore Pakistan(Bilal Gunj)
HS Code:  8544492100
Production Capacity:  with Annual Production of 68000km

Product Description

Specifications
1. Household lowvoltage wires
2. Voltage rated at 450/750V
3. CCC approved
4. OEM order taken
5. MOQ 10km

Electrical Copper Wire (BV)

Single copper solid conductor

Wire's area range from 1.5mm² To 400mm²

Usage

It is used on illumination of power devices with A. C. At a rated voltage 450/750V.

Flame resisdent type wire (ZR-BV)

This type of wire are hardly to get fire or the continuous burning of cable is certainly limited when the wire is on fire.

Flame resisdant performence passed the standard GB12666.5-90 and IEC332-3's request.

Fire-resistance feature wire(NH-BV)

This type of wire can operate normally and safely for some time when the wire is on fire.

Fire-resisdant performence passed the standard GB12666.5-90 and IEC331's request.

Low smoke, low halogen wire(WD-BV)

The main feature of this kind of cable is low smoke emission and low release of HCl gas when the cable gets burning.

Passed the standard GB12666.5-90 and IEC332-3's request.

Light transmittance less than 35%, HCl gas release less than 100mg/g

Attention

Operating temperature

--105 type not exceed 105° C

--other type not exceed 70° C

Ambient Temperature when operating

--Above 0 ° C

Laying bending radius request

--For O. D. Less than 25mm, the laying bending radius should not less than 4 time O. D.

--For O. D. Not less than 25 mm, the laying bending radius should not less than 6 time O. D.

Rated
Voltage
(V)
Cross-section
  area
(mm² )
Conductor
  type
Upper
Limited
of O. D.
(mm)
Max. D. C.
Resistance
at 20 ° C
(O )
Min.
Insulation
resistance
at 70 ° C
(MO /km)
Current Rating
  when laid in
the air at 25 ° C
(A)
Weight of cable
Cu core Al Core Cu Core Al core Cu Core Al core
300/500 0.75 1 2.4 36.0   0.015 13   8.3  
0.75 2 2.6 24.5   0.012 17   10.9  
0.75* 1 2.8 24.5   0.014 17   11.8  
1.0 2 2.8 18.1   0.011 20   13.7  
1.0*   3.0 18.1   0.013 20   14.8  
450/750 1.5 1 3.3 12.1   0.011 25   20.0  
1.5 2 3.5 12.1   0.010 25   21.3  
2.5 1 3.9 7.41 12.1 0.010 34 27 31.5 15.4
2.5 2 4.2 7.41   0.009 34   34.4  
4 1 4.4 4.61 7.41 0.0085 44 35 46.8 21.5
4 2 4.8 4.61   0.0077 44   50.0  
6 1 4.9 3.08 4.61 0.0070 58 45 66.7 29.10
6 2 5.4 3.08   0.0065 58   71.0  
10   7.0 1.83 3.08 0.0065 79 65 118.0 48.63
16   8.0 1.15 1.83 0.0050 111 85 178 69.02
25   10.0 0.727 1.15 0.0050 146 110 280 107.16
35   11.5 0.524 0.727 0.0040 180 138 378 139.39
50   13.0 0.387 0.524 0.0045 282 175 508 189.74
70   15.0 0.268 0.387 0.0035 281 220 717 257.71
95   17.5 0.193 0.268 0.0035 344 265 991 352.91
120   19.0 0.153 0.193 0.0032 397 310 1228 433.21
150   21.0 0.124 0.153 0.0032 456 360 1511 536.38
185   23.5 0.0991 0.124 0.0032 519 420 1894 667.66
240   26.5 0.0754 0.0991 0.0032 592 510 2465  
300   29.5 0.0601 0.0754 0.0030 685 600 3089  
400   33.0 0.0470 0.0601 0.0028 799 700 3935  